Various codes of PSC inspection and how to present to PSCO in case IOPP equipment is not working
Following are the various codes which are used to represent Action to be taken by vessel against the deficiency reported:- Deficiency Action Codes 10 deficiency rectified 15 rectify deficiency at next port 16 rectify deficiency within 14 days 17 rectify deficiency before departure 18 rectify deficiency within 3 months 30 detainable deficiency 99 other (specify) Note: For ISM deficiencies, only code 10, 18 and 30 can be used. Restrictions on Updating Codes Both codes 15 and 16 can only be updated to code 10. Code 17 can only be updated to code 10, 15, 16 and 99. Code 18 can only be updated to code 10. Code 30 can only be updated to: - code 10 or 18 (ISM def.) - code 10 or 99 (non - ISM def.) Code 18 can only be updated to code 10. We will discuss one case where 15 ppm equipment has started malfunctioning just before the arrival of the port. After investigating it was found that the coalescer filter has become very dirty and because o...